Installation Procedure
English
Installation Procedure
CAUTION
Pipe outlet
Cut the pipe outlet to the exact pipe size. In addition,
remove foreign substances and burr aroud the outlet.
Perform cutting with only a cutter (ex. nipper)and never
tap with a hammer near the pipe outlet. Otherwise, it may
cause product damage such as warping of the cabinet.
After connecting the pipes with Pipe outlet, plug the space
around the pipes.
After connecting the pipes, proceed exactly as directed in
the guide to prevent interference with the internal parts.
Tighten the nuts to the specified torques. If overtightened,
the nuts could be broken so refrigerant may leak.
Protect or enclose refrigerant tubing to avoid mechanical
damage.
After installing pipes, block the unused knock hole to
prevent small animal from entering. However, the radiant
heat hole(A) should be able to intake air.
Step 7 Optional: Cutting and flaring
the pipes
1 Make sure that you have the required tools available.
(pipe cutter, reamer, flaring tool, and pipe holder)
2 If you wish to shorten the pipes, cut it with a pipe
cutter, taking care to ensure that the cut edge remains
at a 90° angle with the side of the pipe. Refer to the
illustrations below for examples of edges cut correctly
and incorrectly.
Pipe cutter
Pipe
Oblique
Burr
90°
Rough
3 To prevent any gas from leaking out, remove all burrs
at the cut edge of the pipe, using a reamer.
4 Slide a flare nut on to the pipe and modify the flare.
Flare Flare
Pipe
L
A
90° ±2°
R 0.016 to 0.032 inch
(0.4 to 0.8 mm)
45° ±2°
D
D
Outer Diameter
(D)
Depth (A) Flare dimension (L)
mm inch mm inch mm inch
Ø6.35 1/4 1.3 0.051 8.7 to 9.1 0.34 to 0.36
Ø9.52 3/8 1.8 0.071 12.8 to 13.2 0.50 to 0.52
Ø12.70 1/2 2.0 0.079 16.2 to 16.6 0.64 to 0.65
Ø15.88 5/8 2.2 0.087 19.3 to 19.7 0.76 to 0.78
Ø19.05 3/4 2.2 0.087 23.6 to 24.0 0.93 to 0.94
5 Check that the flaring is correct, referring to the
illustrations below for examples of incorrect flaring.
1
2
3
Correct
Inclined
Damaged
surface
Cracked Uneven
thickness
DB68-11579A-00_IM_RAC oudoor_AA_EN_.indd 16DB68-11579A-00_IM_RAC oudoor_AA_EN_.indd 16 2022-01-12 오후 1:37:512022-01-12 오후 1:37:51