Samsung AS09HPB - Fault Diagnosis by Symptom

Samsung AS09HPB
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics12-2
1. Checklist :
1) Is input voltage normal?
2) Is AC power linked correctly?
3) Is input voltage of DC regulator IC KA7805 (IC02) normal?(11VDC-12.5VDC)
4) Is output voltage of DC regulator IC KA7805 (IC02) normal?(4.5VDC-5.5VDC)
2. Troubleshooting procedure
12-2 Fault Diagnosis by Symptom
12-2-1 No Power (completely dead)-Initial diagnosis
does not operate
Yes
Yes
Yes
Yes
Check the display board
operate
Press the
Power Button on the
remote control unit to operate the
air conditioner
Reconnect wires correctly
No
Check whether
2 wires of power cord are
connected correctly to the
terminal block and
control board.
Replace fuse
No
Check whether
the fuse on the control board is normal.
FUSE(F701) : T3.15[A]/250[V]
PCB should be replaced
No
Check the output of
SMPS on the control board.
Input power: AC230±15%[V]
IC02 Input: DC12[V]
IC02 output: DC5[V]
Unplug the power cord and
plug it after 30 seconds
Check the indoor unit
control board
Check the setting temperature
24437A(1)_1 1/16/05 9:58 PM Page 12-2