1 AUTO MODE : In this mode, operation mode
(COOL,HEAT) is selected au
tomatically by the
room temperature of initial operation.
(Set Temp. : 24°C)
2 COOL MODE : The unit operates according to
the difference between the setting and room
temperature.(16°C ~ 30°C)
3 HEAT MODE : The unit operates according to
the difference between the setting and room
temperature.(16°C ~ 30°C)
*Prevention against cold wind : In order to prevent
the cool air from flowing out at the heat mode,
the indoor fan does not operate or orperates
very slowly in the following cases. At this time,
the indoor heat exchanger will be preheating.
- For 3~5 minutes after the initial operation
- For deicing operation
- The operation of an indoor fan in accordance with
the temperature of an indoor heat exchanger.
*High temperature release func
tion: It is a function to
detect an outdoor overload by the sensor of an indoor
exchanger and to turn
the outdoor fan or the compressor
ON/OFF for safety.
*Deice : Deicing opertion is controlled by indoor uni
t's
heat exchanger temperature and accumulating time of
compressor's operation. Deice ends by sensing of the
processing time by deice condition.
4 DRY MODE : Has 3 states, each de
termined by room
temperature.
The unit operates in DRY mode.
*Compressor ON/OFF time is controlled compulsorily
(can not set up the fan speed, always breeze)
*Protective func
tion : Low temperature release.
(Prevention agains
t freeze)
9 EVAP. CLEAN MODE : The unit operates according
to
the below.
*When the air condi
tioner is turned off.
The Evapora
tor clean indicator on the indoor unit
display appears and the Evaporator cleaning function runs.
*When the air conditioner is turned on.
The Evapora
tor clean indicator on the indoor unit
display appears and the Evapora
tor cleaning function
runs after stopping the air conditioner opera
tion.
*Evaporator cleaning time can vary, depending on the
previously used mode.
1) Auto(COOL),COOL,DRY MODE :
approximately 30 minutes.
2) Auto(HEAT),HEAT,FAN MODE :
approximately 15 minutes.
6 GOOD'SLEEP MODE : Default good'sleep time is se
t to
8 hours. But the good'sleep time can be set up to 12
hours, increasing in 30 minu
te unit up to first 3 hours and
in hourly unit after first 3 hours.
*Temperature/Fan speed/Air swing can be adjusted after
setting good'sleep in HEAT MODE.
*Tempera
ture can be adjusted and the air conditioner
automatically adjusts Fan speed/Air swing after setting
good'sleep in COOL MODE.
7 FAN SPEED : Manual (3step),Auto (4 step)
Fan speed automatically varies depending on both the
difference between se
tting and the room temperature.
8 COMPULSORY OPERATION : For operating the air
conditioner without the remote control.
*The air conditioner starts up in the most suitable mode
for the room temperature.
5 TURBO MODE : This mode is available in AUTO,
COOL,HEAT,DRY,FAN MODE.
When
this button is pressed at first, the air conditioner
is operated "powerful" state for 30 minutes regardless
of
the set temperature, room termperature.
When
this button is pressed again, or when the
operating time is 30 minutes, turbo operation mode is
canceled and re
turned to the previous mode.
*But, if you press the TURBO button in DRY or FAN
mode
that is changed with AUTO mode automatically.
The temperature of indoor heat exchanger indoor fan speed
below 28°C off
28°C~below 34°C LL speed
34°C~below 40°C L speed
above 40°C Setting speed
Option Mode
Heat pump option selec
ted Auto mode
Cooling only option selected Cooling mode