Operating Instructions and Installation
Samsung Electronics 3-5
No Parts Procedure Remark
4 PBA 4) Loosen the Motor Feedback connector(CN44).
Caution:
When you separate the connector,
pull pressing the locking button.
5) Loosen the Humidity sensor connector(CN42).
Option connector.
Caution:
When you separate the connector,
pull pressing the locking button.
6) Loosen the MPI connector(CN81).
Option connector.
Caution:
When you separate the connector,
pull pressing the locking button.
7) Loosen the Relay #4 blue-connector(RY71).
Caution:
The terminal is locking type.
So, when you separate terminals,
pull pressing the button.
Button