ENGLISH
37
Fixing the Ourdoor Unit in Place
Install the outdoor unit to a stable base to avoid the generation of noise and
vibration, especially when installing the unit close to a neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a height,
to an appropriate support (wall or ground).
1
Place the outdoor unit as indicated on the top of the unit to let the
discharged air out properly.
2
Fix the outdoor unit to an appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around the
outdoor unit so that the fan can operate correctly.
'X' mm
Rubber leg
'Y m ' m
**
Model X Y
**
** **
1
09/12/13 454 254
8/19
538 290
****
18/24
****
25
5
660
43 3
340
19
•
•
S
Outdoor size is dierent for model series. Please select correct outdoor
plate size.
ecure the rubber leg to prevent the generation of noise and vibration.
Final Check and Trial Operation
To complete the installation, perform the following checks and tests to
ensure that the air conditioner operates correctly.
Check the followings:
• Strength of the installation site
• Tightness of pipe connection to detect gas leak
• Electric wiring connection
• Heat-resistant insulation of the pipe
• Drainage
• Grounding conductor connection
• Correct operation (follow the steps below)
1. Press the Power
button and check the following:
The indicator on the indoor unit lights up.
3. Press the Air swing
button and check the following:
4. Press the Power button to stop the operation.
2. Press the Mode button to select Cool or Heat mode.
In Cool mode, use Temp + or - button and set the temperature at 16°C.
In Heat mode, use Temp + or - button and set the temperature at 30°C.
Cooling mode (indoor unit check) - Inlet air temp. - Outlet air temp : From 10°C to 12°C ( indicative delta T)
Heating mode (indoor unit check) - Outlet air temp. - Inlet a
ir temp : From 11°C to 14°C (indicative delta T)
• Approximately 3~5 minutes later, outdoor unit will start to operate and the Cool or Warm air will blow out.
• After 12 minutes of stationary condition check the indoor unit air treatment:
• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe
place.