4.AlignmentandTroubleshooting
ErrorCode
U2-6122
U2-6142
Errormessage
Error#U2-6122Turnoffthenon
Error#U2-6142Turnoffthenon
Symptom
LSUMotordoesnotworknormally./LSUHsyncsignalisabnormal.
Troubleshootingmethod
1)CheckiftheLSUharnessonthemainboardisconnectedproperly.
2)IfitisOK,checkthattheLSUharnessonLSUboardisconnectedproperly.
3)CheckiftheLSUharnessisdefective.
4)Iftheproblempersists,replacetheLSU.
5)IftheproblempersistsafterreplacingLSU,replacethemainboard.
4-43Copyright©1995-2013SAMSUNG.Allrightsreserved.