4.AlignmentandTroubleshooting
ErrorCode
A3–3311
A3–3312
Errormessage
Error#A3-3311Callforservice
Error#A3-3312Callforservice
Symptom
Theoutertemperaturesensorisdefective.
Troubleshootingmethod
1)Turnthemachineoffthenon.Iftheerrorpersists,turnthemachineoffagain.
2)Enterthetechmode.Checkthetemperaturesensoroutput.
3)Ifthesensorisdefective,replaceit.
4)IfthetemperaturesensorisOK,replacethemainboard.
ErrorCode
A3–3320
Errormessage
Notproperroomtemp.Moveset
Symptom
Thevalueoftheoutertemperaturesensorisoutofnormalarea.
Troubleshootingmethod
1)Checkifthemachineisinstalledintheproperarea.
2)Ifthetemperaturesensorisdefective,replaceit.
4-31Copyright©1995-2013SAMSUNG.Allrightsreserved.