3. Disassembly and Reassembly
3-10 Replacement of Air Filter
Parts Explaination Photo Explaination
Air Filter
Plastic Spacer Pins
1. Pull out the spacer pins at both ends of the Air Filter.
Then the locking clamps inside are released.
2. Lift the Air Filter off the post carefully.
NOTE
: Spacer pins are not detachable from the Air
Filter.
3-11 Replacement High Voltage Capacitor
Parts Explaination Photo Explaination
High
Voltage
Capacitor
H.V.Capacitor
NOTE : It is not necessary to remove
Magnetron in order to remove HVC.
1. Remove the outer panel and back cover.
2. Discharge HVT wire and H.V.Fuse
3. Remove HVT wire and H.V.Fuse.
4. Remove screw securing HVC bracket.