TROUBLE SHOOTING & ERROR MODE
7
148 | SAMSUNG
Error Code & Check
7-4. Error Code & Check
Checking area
Indoor unit thermistor sensor
PCB of the indoor unit
Meaning
Indicators
Error code
(wired remote controller)
*1
*5
*6
*9
*A
*C
*D
*L
Indoor unit thermistor sensor error
Indoor unit pipe sensor
PCB of the indoor unit
Indoor unit pipe sensor error
Outdoor unit thermistor sensor
PCB of the outdoor unit
Outdoor unit thermistor sensor error
Drain pump, Float switch
Drain system
Float switch error
Communication cables of indoor and
outdoor units
PCB of indoor and outdoor units
Indoor and Outdoor communication
error
Wired remote controller cables,
Wired remote controller
Main/Sub PCB of the indoor unit
Wired remote controller
communication error
Outdoor pipe sensor
PCB of the outdoor unit
Outdoor pipe sensor error
Three phase power connecting
PCB of the outdoor unit
Three phase power incorrect
connecting error(In case of three
phase power models)
: OFF : Blinking : Blinking at once : Blinking alternately
The asterisk mark “ * ” + “ERROR” CODE of wired remote controller stands for the set number.
ex) ERROR CODE “39” is the FLOAT SWITCH OPEN ERROR of SET no.3.
Indicators means wireless Remote controller Receiver & display.
▲▲
▲▲
▲▲
Timer