104
Ⅶ.TROUBLESHOOTING
5) Defect related to the LCD
When the camera is connected to the external
monitor, images are displayed correctly
Check the connection of LCD F PCB
When the LCD is pressed, the camera is
turned off
Check the defect of CCD
Images are not displayed on the LCD - Check the connection
The LCD is whitened - Check the short of F PCB pattern
Interference of MAIN PCB and CF_41
- Check the location of tape on the bakc of the LCD
Check the protect tape of BACK LIGHT soldering
Check the soldering condition of BACK LIGHT
Defect of BACK LIGHT
NO
YES
Check the
soldering condition
of BACK LIGHT
Check the protect
tape of BACK
LIGHT soldering
CF_41

Related product manuals