EasyManua.ls Logo

Samsung Digimax S500 - Main Troubleshooting

Samsung Digimax S500
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92
Ⅶ.TROUBLESHOOTING
2. Main troubleshooting
1) The power can't be turned on
Check : Power input
(Battery, Adaptor, etc.)
Check the assembly
condition of various
connectors.
Current electricity :
280~330mA
Check connection : Between the Main PCB and the TOP F PCB.
Check soldering : Battery contact
Check connection : Between the Main PCB and the FLASH F PCB.
Flash memory defect.
Upgrade the Full version Firmware
Power PCB defect
Check the power of TPs
on the MAIN PCB
Check the output of TPs
Check the connection between
MAIN PCB and TOP F
Check the soldering condition of
FLASH F PCB and MAIN PCB
Check the soldering condition
of BATTERY CONTACT