Lists critical safety warnings for installation and operation to prevent severe injury or death.
Details compatibility and specifications for combining outdoor units for system capacity.
Explains requirements for constructing a stable and properly drained base for the outdoor unit.
Covers fundamental principles for pipe installation, pressure, and necessary tools.
Detailed steps and precautions for cutting and flaring refrigerant pipes correctly.
Instructions on how to connect flared pipes, including torque specifications and oil application.
Step-by-step instructions for connecting refrigerant pipes to the outdoor unit, with welding cautions.
Rules and examples for installing pipes and branch joints between multiple outdoor units in a module.
Guidelines for selecting pipe sizes based on capacity and length, including increasing size for long runs.
Table detailing pipe sizes for outdoor units based on capacity and maximum pipe length.
Guides on selecting pipe sizes for branch joints based on indoor unit capacity and pipe length.
Tables listing MCA and MFA ratings for circuit breakers and power cables for various outdoor unit models.
Continues listing MCA and MFA ratings for compact and heat recovery outdoor unit series.
Instructions for connecting cables to terminals using ring terminals, including torque values and cable tie usage.
Step-by-step instructions for performing an air tightness test using nitrogen gas.
Detailed procedure for vacuum drying refrigerant pipes and indoor units using a vacuum pump.
Guidelines and material specifications for insulating refrigerant pipes and branch joints.
Steps for insulating distribution headers and branch joints, including proper attachment methods.
Instructions for insulating pipes, branch joints, and connections, including EEV kit considerations.
Guide to the automatic pipe-address setting operation, including pre-operation checks and temperature ranges.
Detailed steps for initiating and running the auto pipe pairing operation, including display indicators.
Essential checks before supplying power, including insulation resistance and voltage/phase verification.
Comprehensive checklist covering unit installation, pipes, drain, wiring, and settings.
Step-by-step guide for auto trial operation and post-operation checks for normal function.