Connecting the assembly cable
2 . Open the cover panel.
3 . Remove the screw securing the connector cover.
4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
• Eachwireislabeledwiththecorrespondingterminalnumber.
5 . Pass the other end of the cable through the 65 mm hole in the wall.
6 . Close the connector cover by tightening the screw carefully.
7 . Close the cover panel.
8 . Remove the terminal board cover on the side of the outdoor unit.
9. Connect the cables to the terminals as seen in the picture.
• Eachwireislabeledwiththecorrespondingterminalnumber.
• DRED(DemandResponseEnablingDevice)maybesuppliedbythepowersupplyutility.
Indoor unit
Outdoor unit
• Alsocircularterminalmustbematchedwithscrewsizeinterminalblock.
• Afterconnectingthecables,makesureterminalnumbersontheindoor/outdoorunitmatches.
• PleaseensurethatPower&Communicationcablesareseparated,theymustnotbeinthesamecable.
• Donotconnect240VdirecttoDRED’sorF1/F2terminalblocks.
09/12/18/24 30
DRED
DRM3
C
DRM2 DRM1
1(L)
2(N)
F1
F2
1(L)
2(N)
F1
F2
F1
F2
DRED
DRM3
C
DRM2 DRM1
1(L)
2(N)
1(L) 2(N)
F1
F2
1(L)
2(N)
F1
F2
L N
F1
F2
L
N
1. Extend the assembly cable if necessary.
• Donotconnecttwoormoredierentcablestoextendthelength.
It may cause re.
When you install the unit, makerst refrigerant connections and then electrical connections.
Connect the air conditioner to grounding system before performing the electrical connection.
If unit is uninstalled, rst disconnect electrical cables, then refrigerant connections.
If the outdoor unit is more than 8 meters away from the indoor unit, you must extend the cable. The maximum length of the
cable is 15(09/12) / 30(18/24/30) meters.
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
DREDterminalblock:ConnectiontoDREDRelayorSwitch.
A3050 Australia_IB&IM_DB68-05206A_EN.indd 46 2014/12/29 19:07:39