11
6. Technical point
4) The water level data at each course
5) The other water level data
If water level is 15KHZ below or 30 KHZ above , sensor-pressur is out of order so needs changing.
The water data unter each conditon
1st water supply (only preparation)
24.60 1st water supply level to washing tub
Overflow error
20.50 The water supplied reach 2/3 of door
Bubble
detectingatwashing/rinse/dehydrating
25.45 Bubble -detecting water level
Bubble detecting rinse water level
21.60 The water level which can detect bubbles
Water level which can open door
23.80
over
It is possible to open the door
Water level which can drive heater
24.50 Safety water level of wash heater
Water level which can reset the drain
24.50 The water level can be detected after 1st draining
Water level
Course
Default water level(khz)
Supplemetary water
START(Khz)
Supplemetary water
end(khz)
Cotton
Washing
23.60 24.20 23.90
Rinse
23.00 24.20 23.90
Coloureds
Washing
23.60 24.20 23.85
Rinse
23.00 24.20 23.90
Synthetics
Washing
23.60 24.20 23.90
Rinse
23.10 24.20 23.90
Delicates
Washing
23.25 23.00 23.70
Rinse
23.00 24.20 23.90
Wools
Washing
23.00 23.00 23.70
Rinse
23.80 23.80 23.50
Quick
Washing
23.60 24.20 23.90
Rinse
23.10 24.20 23.80
unit:Khz
unit:Khz