6. Technical point
1) Motor on/off time at each course
Motor on/off time is measured in cold water, in heating time motor on/off time is 10 sec on and 5sec off in
the cotton course, beside cotton course, in the other course motor on/off time is the same with that of cold
water use.
2) Final dehydrating r.p.m at each course
You can change the r.p.m to the above a table by use spin button under no spin situation.
3) The water supply control at each process cycle
Model
Process cycle
F1015J
Washing
Cold water 5L/min / cold 10L/min
Rinse
Cold 10L/min
Final rinse
Cold water 5L/min + cold 10L/min
Course
Washing Rinse
Motor r.p.m
Cw Off Ccw Off Cw Off Ccw Off
Cotton
13 3 13 3 10 5 10 5 50
Coloureds
11 4 11 4 10 5 10 5 50
Synthetics
7 8 7 8 7 8 7 8 40
Delicates
5 10 5 10 5 10 5 10 30
Wools
2 58 2 58 2 28 2 28 25
Quick
12 3 12 3 10 5 10 5 45
Model
Course
F1015J
Cotton
1000
Coloureds
1000
Synthetics
800
Delicates
600
Wools
400
Quick
1000
unit:sec
unit:rpm