www.jouleuk.co.uk | www.joule.ie
70
Potable System
First you must ensure that the pressure in the expansion vessel is the same as the setting of the pres
-
sure reducing valve i.e. 3 bar (45PSI). The valve is of the Schrader car tyre type.
Check all the connections for water tightness including any factory-made connections such as the
immersion heater and the temperature and pressure relief valve.
Prior to lling, open the hot tap furthest away from the cylinder to expel air. Open the cold main isola
-
tion valve and allow the unit to ll. Once the cylinder has been fully commissioned it should be heated
to its normal operating temperature.
Commissioning
7
System
Smart Plumb Compact Installation
Heating System
The ll ush and ow meter is an important com-
ponent of any heat pump system. It is provided
in all Joule Heat Pump kits. For all heat pump
systems a ow rate of over 16 l/min is required.
It provides connections for the ll and ush ports
of the heating system ush pump for installation
and ongoing servicing. See page 26.