Checking process
Attach the FA 50mm lens on the camera and set the iris to A position.
Set the camera as followins
Exposure: Av mode, Focus: AF, Focus point: Center, WB: AWB, Size / Quality: 10M / Super fine (Default),
Saturation / Sharpness / Contrast: Default
Select the open iris with Av dial.
Set the Chart / Scale / Light as shown. Brightness of the chart (White part of the chart is over EV12).
Use the tripod to prevent the camera shake.
Keep the distance between the camera and the chart 1m.
Block the lens and press the shutter button halfway down to set the distance to infinity.
Match the focus point and chart (border between the black and white part) and take 2 images.
Select the minimum distance and take 2 image. To check the vertical sensor, take images vertically.
Open the images with the image viewer.
Compare the image and the scale of the chart to check the focus.