Ⅲ.ADJUSTMENT
■■
Checking process
① Attach the FA 50mm lens on the camera and set the iris to A position.
② Set the camera as followins
Exposure: Av mode, Focus: AF, Focus point: Center, WB: AWB, Size / Quality: 10M / Super fine (Default),
Saturation / Sharpness / Contrast: Default
③ Select the open iris with Av dial.
④ Set the Chart / Scale / Light as shown. Brightness of the chart (White part of the chart is over EV12).
Use the tripod to prevent the camera shake.
⑤ Keep the distance between the camera and the chart 1m.
⑥ Block the lens and press the shutter button halfway down to set the distance to infinity.
⑦ Match the focus point and chart (border between the black and white part) and take 2 images.
⑧ Select the minimum distance and take 2 image. To check the vertical sensor, take images vertically.
⑨ Open the images with the image viewer.
⑩ Compare the image and the scale of the chart to check the focus.