156
Ⅲ.ADJUSTMENT
2. Adjusting the metering sensor position
Equipment : Pen light or similar kinds of lights
* Mirror must be down..
① Block the magnifying glass from the light with hand.
② By changing the light angle, emit the light to the light receiving elecments to find the position of light on the
first mirror.
* To see the light receiving element easily, attach the lens
③ Do not incline the light receiving element as shown.
Pen light
Sensor
1st mirror
Spot metering frame
Light receiving element(0-J100)