162
Ⅳ.SERVICEINFORMATION
1. The order of assembly and disassembly
■ Cautions
1. To protect the circuit from the power source, use the electric conduction mat and wrist strap.
2. This camera use the Pb free solder.
The color of the solder is white and the melting temperature is high.
The melting temperature may cause the camera brokage. To prevent the camera brokage, solder them
quickly and use the exclusive iron that can melt the Pb free solder.
Set the temperature of the iron to 340360℃.
3. Connector and PCB attached on the PCB are sensitive parts.
Do not treat them by force and take care of breakage when they are assembled or disassembled.
Tip: Before disassembling the parts, mark the positions with a marker.
■ Adjustment flow of changing the
The following diagram is for the T100 main circuit when it is changed.
Changing the T100
[Adjustment]
● Writing the FW for Chnaged
T100
● Writing the default data
SR Unit adjustment
Single Reflex part adjustment
(Adjustment program)
* Reseting the data is not
available
SR Gain Adjustment
Digital part adjustment
Shutter speed adjustment
(Histogram)
[Operation check]
* SR operation checking can
be skipped