EasyManua.ls Logo

Samsung GX-10 - Page 202

Samsung GX-10
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
202
Ⅳ.SERVICEINFORMATION
16. [Adjutment] Initial adjustment of the changed T100
Equipment
SD card for the adjustment (FW for the changed T100 and writing the initial data)
TV monitor
Exclusive video cable
Circuit tester
AC adapter (or DC cable for 76830 / Above DC 8.3V, 3A power source)
16-1. Preparation
Connec the Video cable to the TV monitor.
Short circuit the contact point (T200) of the Main SW with soldering.
16-2. Power checking
Insert the DC cable (DC 8.3V, 3A) on the power source.
Insert the DC cable on the camera. Take care of the short circuit or leaks
[Caution] If there is over current, disconnect the power source immediately. (When the metering is off, current
consumption is about 320mA)
Disconnect the DC cable.
16-3. Writing the FW for the changed T100
[Caution] When the 0-T100 is changed, you must write this FW. In the rest cases, Writing this FW is not
required.
For the detail information, refer to the e-leaning part of the web-site.
16-4. Writing the initial FW
When the initial FW is written, all of EEPROM data is deleted.
[Caution] When the 0-T100 is changed, you must reset the camera. In the rest cases, Reseting the camera is
not required.
For the detail information, refer to the e-leaning part of the web-site.