202
Ⅳ.SERVICEINFORMATION
16. [Adjutment] Initial adjustment of the changed T100
Equipment:
□SD card for the adjustment (FW for the changed T100 and writing the initial data)
□TV monitor
□Exclusive video cable
□Circuit tester
□AC adapter (or DC cable for 76830 / Above DC 8.3V, 3A power source)
16-1. Preparation
① Connec the Video cable to the TV monitor.
② Short circuit the contact point (T200) of the Main SW with soldering.
16-2. Power checking
① Insert the DC cable (DC 8.3V, 3A) on the power source.
② Insert the DC cable on the camera. Take care of the short circuit or leaks
[Caution] If there is over current, disconnect the power source immediately. (When the metering is off, current
consumption is about 320mA)
③ Disconnect the DC cable.
16-3. Writing the FW for the changed T100
[Caution] When the 0-T100 is changed, you must write this FW. In the rest cases, Writing this FW is not
required.
For the detail information, refer to the e-leaning part of the web-site.
16-4. Writing the initial FW
*When the initial FW is written, all of EEPROM data is deleted.
[Caution] When the 0-T100 is changed, you must reset the camera. In the rest cases, Reseting the camera is
not required.
For the detail information, refer to the e-leaning part of the web-site.