57
Ⅲ.ADJUSTMENT
3-3. Setup the master body and standard lens
① Set the mode dial to [M]
② Set the focus mode lever to [MF].
③ Set the OPS lever to [OFF].
④ Attach the metering standard F8 set ring (for adjustment) on the body.
⑤ Set the standard lens to F8.
3-4. Tuning process
① Connect the AC adapter to the camera.
② Connect the camera to a PC with the USB cable.
③ Turn on the camera.
④ Set the light box to LV12.
⑤ Match the center of the camera and the center of the light box and block the camera and front side of the
light box with the blocking curtain.
⑥ Run the [76830 MTest.exe] on the [EXE] folder.