Ⅲ.ADJUSTMENT
17-2. Preparation
① Set the AF lever to MF.
② Attach the OPS Unit tool to the camera body.(↓)
③ Arrange the camera on a stable table. The lens faces the bottom of the table.
④ When the T100 circuit is changed, check the CCD ID No..
17-3. Adjustment process
① Turn on the PC.
② Connect the camera to the PC with the USB cable and insert the AC adapter. Turn on the camera.
③ Check the Hot plug icon on the desktop.
④ Run the [K10D SR Operation.exe] in the adjustment software folder.
⑤ Adjustment program runs.
⑥ Click the [Start] button.