4-29
4. Troubleshooting
4-3. Factory Mode Adjustments
4-3-1 Entering Factory Mode
To enter ‘Service Mode’ Press the remote -control keys in this sequence :
- If you do not have Factory remote - control
MUTEPower OFF 1 8 2 Power On
4-3-2 How to Access Service Mode
Using the Customer Remote
Turn the power off and set to stand-by mode
Press the remote buttons in this order; POWER OFF-MUTE-1-8-2-POWER ON to turn the set on.
The set turns on and enters service mode. This may take approximately 20 seconds.
Press the Power button to exit and store data in memory.
- If you fail to enter service mode, repeat steps 1 and 2 above.
Initial SERVICE MODE DISPLAY State
ADC
Expert D-Settings
ADC Target Expert Gray Scale
ADC Result Expert C-Space
Option Byte Expert Others
White Balance CHECKSUM 0x0000
W/B Movie VisualTEST
EPA Standard Font Data Viewer
Video/Scaler T-PRLAUSC-0038
T-PRLAUSM-0017
MTK-DRV 2.0.25.0
RFS : T-PRLAUS-20071127
2007-12-07
PANEL : 46AM
LN46A550P1FXZA
EDID Success
Option :
0311 1110 5120 8000 0c18
0010 0000 00
DTP-COMP-0052
DTP-LM-0064
Date of purchase : 12/9/2007
Enhancement
SOUND
Dynamic Contrast
LNA+
Hotel Option
EDID
Expert Setting
- “T-TULPUS0-0025” and “T-TULPAUS5-C007” are rmware.......
1.
2.
3.
4.
5.