E-2
WARNING
Safety Precautions
(
Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.)
Always disconnect the air conditioner from the power supply before servicing
it or accessing its internal components.
• Verify that installation and testing operations are performed by qualified
personnel.
• Verify that the air conditioner is not installed in an easily accessible area.
GENERAL INFORMATION
Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to
be able to use it as reference after installation.
For maximum safety, installers should always carefully read the following warnings.
Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air
conditioner is sold or transferred.
This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of
units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be
responsible for damages arising from the use of non compliant units.
The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric
and requirements set forth in the Operating limits table, included in the manual, shall immediately invalidate the warranty.
The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to
be installed in areas used for laundry.
Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.
In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG
stechnical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.
Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations
should be performed by qualified personnel only.
The unit contains moving parts, which should always be kept out of the reach of children.
Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may
cause electric shocks or fires.
Do not place containers with liquids or other objects on the unit.
All the materials used for the manufacture and packaging of the air conditioner are recyclable.
The packing material and exhaust batteries of the remote control(optional) must be disposed of in accordance with current laws.
The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air condi
tioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.
INSTALLING THE UNIT
IMPORTANT:
When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines.
Always disassemble the electric lines before the refrigerant tubes.
Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged,
DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician
has collected the material from the retailer.)
After completing the installation, always carry out a functional test and provide the instructions on how to operate the air
conditioner to the user.
Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to
avoid the occurrence of fires, explosions or injuries.
POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER
Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in
compliance with current local safety standards.
Always verify that a suitable grounding connection is available.
Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is suf
ficient to ensure the operation of any other domestic appliance connected to the same electric lines.
Always verify that the cut-off and protection switches are suitably dimensioned.
Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring
diagram included in the manual.
Always verify that electric connections (cable entry, section of leads, protections) are compliant with the electric specifica
tions and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards
applicable to the installation of air conditioners.
09'FJM_OUTDOOR_28896A_IM_E_11.23.09.indd 2 2009-11-24 9:19:11
Question and Answer IconNeed help?

Do you have a question about the Samsung MH040FXEA2C and is the answer not in the manual?

Samsung MH040FXEA2C Specifications

General IconGeneral
ModelMH040FXEA2C
Cooling Capacity4.0 kW
Heating Capacity4.5 kW
RefrigerantR410A
Weight (Indoor Unit)10 kg
Voltage220-240V
Net Weight (Indoor Unit)10 kg
Power SupplySingle, 50Hz
TypeSplit System Air Conditioner
Energy Efficiency Ratio (EER)12 BTU/W
Power Consumption (Cooling)1134 W

Summary

Safety Precautions

PREPARING THE INSTALLATION

Deciding on Where to Install the Air Conditioner

Guidance on selecting optimal locations for air conditioner units.

Piping outside diameter

Specifications for pipe diameters for connecting indoor and outdoor units.

Piping length and the height

Guidelines for maximum pipe length and height differences between units.

Space Requirements for Outdoor Unit

Recommended clearances around the outdoor unit for proper airflow.

Air Conditioner and Accessories

Lists the components and accessories supplied with the air conditioner.

INSTALLING THE INDOOR UNIT

Installing and Connecting the Drain Hose of the Outdoor Unit

Instructions for connecting the drain hose to the outdoor unit for condensation removal.

Cutting/Extending the Piping

Procedures for cutting, flaring, and preparing refrigerant pipes for connection.

INSTALLING THE OUTDOOR UNIT

Connecting the Cables to the Outdoor Unit

Detailed steps for electrical wiring and connecting power and communication cables.

Transmitter Installation (Optional)

Guide for installing the optional remote transmitter unit.

Checking Correct Earthing

Procedures for ensuring proper grounding of the air conditioner unit.

Fixing the Unit in Position

Guidelines for securely mounting the outdoor unit on a stable base.

COMPLETING THE INSTALLATION

Connecting Up and Purging the Circuit

Steps for connecting refrigerant pipes and removing air from the system.

Adding Refrigerant

Guidelines for adding refrigerant based on pipe length.

Important information regulation regarding the refrigerant used

Regulations and precautions concerning the use of fluorinated greenhouse gases.

Performing Leak Tests

Methods for checking refrigerant leaks using nitrogen or R-410A.

Pipe Installation with Indoor Units

Routing and connecting pipes for multi-unit systems.

Switch Setting and Testing Operation

Configuring unit settings and performing functional tests after installation.

Troubleshooting

Guidance on identifying and resolving common error codes displayed by the unit.

Explaining Operations to the Owner

Demonstrating basic functions and features to the end-user.

Pump Down Procedure (When removing the product)

Safely recovering refrigerant before unit removal or disposal.

Related product manuals