4.Troubleshooting
4.2.MeasurestobetakenwhentheProtectionCircuitoperates
4.2.1.OperationofPowerBlockProtectionCircuit
CasesoftheSMPSProtection.
1)IfthereisovercurrentattheAMPIC.(SpeakerWireShort)
2)IftemperatureoftheAMPICisover150.
3)Thereisnopowersupplyforamp.
ProtectionCircuitoperateswhenpowerproblemoccursintheSMPS.
Protection
LocationPinNo.
OpenShort
Remark
+5.3V(2~3#)XX
+PVDD(+34V)(13&15#)XX
+PVDD(10#)XX
MX-F730/F730D
SMPSPCB
CNM802
P-ON(+5V)(7#)XX
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-5