19
Clearance for wall mounting
Installing the outdoor unit only
When installing close to the wall, maintain a sufficient clearance in order to secure air flow.
Clearance for OH46F/OH55A/OH55F ( ): 50 mm or more
Clearance for OH75A/OH75F/OH85F ( )
Example 1) Exposure to direct sunlight: 200 mm or more
Example 2) Atmospheric temperatures under 35 ℃ without direct sunlight: 60 mm or
more
Add partitions between the inlet and outlet to prevent discharged air from flowing back
into the inlet.
"
If the unit is subjected to excess heat due to an insufficient gap, this may cause a
malfunction, which will not be covered by the warranty.
If the distance between the back of the product and the wall is too large, the following
types of partitions can be installed.
45 mm
50 mm
Min. 95 mm
OH46F: 570 mm
OH55A/OH55F: 650 mm
650 mm
Wall or
obstacle
OH46F/OH55A/OH55F
Partition
Partition
Side view
Back
Back
OH75A/OH75F/OH85F
Wall or
obstacle
Partition