Partition design guide
For semi-outdoor units, add partitions between the inlet and outlet to keep air paths separated.
Partitions should fit perfectly inside the enclosure unit, with no gap between the semi-outdoor unit and enclosure
unit. If there is a gap, use a foam tape to fill it.
Partition
Foam tape
Install an anti-backflow screen around the 4 sides of the edges of the protrusion on the rear cover.
When installing the display along with an enclosure, ensure adequate clearance (A) between the back of the
enclosure and surrounding objects for proper flow of air.
Example 1) Exposure to direct sunlight: 100 mm or more
Example 2) Atmospheric temperatures under 35 without direct sunlight: 50 mm or more
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
A
Wall