Follow the instructions provided in this guide when installing the product.
Samsung will not provide warranty coverage for problems that may arise as a result of failure to follow the guide.
The color and shape of the product may vary. In addition, instructions in the installation guide may change without prior notice when
necessary to improve the product.
Window Display
Installation Manual
Question and Answer IconNeed help?

Do you have a question about the Samsung OM75R and is the answer not in the manual?

Samsung OM75R Specifications

General IconGeneral
Touchscreen-
Response time8 ms
Display diagonal75 \
Display brightness4000 cd/m²
Display technologyVA
Native aspect ratio16:9
Vertical scan range24 - 75 Hz
Horizontal scan range15 - 135 kHz
Contrast ratio (typical)5000:1
Display diagonal (metric)189 cm
Dynamic contrast ratio marketing nameMega Contrast
USB portYes
OrientationHorizontal/Vertical
Product colorBlack
Product designDigital signage flat panel
Placement supportedIndoor
Panel mounting interface400 x 400 mm
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Energy efficiency scaleA+++ to D
Power consumption (sleep)0.5 W
Power consumption (standby)- W
Annual energy consumption600 kWh
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)10 - 80 %
Package depth225 mm
Package width1890 mm
Package height1144 mm
Package weight50500 g
Weight and Dimensions IconWeight and Dimensions
Depth82.6 mm
Width1703.1 mm
Height981.2 mm
Weight38000 g

Summary

Prior to Installation

Precautions for installation

Semi-outdoor units not for outdoor use; avoid oil mist and tempered glass for warranty.

Rotation and tilt angle

Display supports landscape/portrait orientation and a maximum 15° forward tilt from the wall.

Clearance for installation by windows

Maintain 100mm clearance (A) and ambient temp below 30°C (B) for proper air flow near windows.

Clearance for wall mounting

Maintain 100mm clearance (A) and ambient temp below 30°C (B) when mounting to a wall surface.

Required clearance when installing an enclosure

Ensure adequate clearance (A) for air flow with enclosures: 100mm for sun, 50mm without sun.

Installing the wall-mount

Use Samsung WMN6575SE mount for 100mm clearance. Select M8 screw longer than 46mm.

Air flow direction

Cooling fan draws external air via inlet, discharges warm air via outlet. Clear obstacles for air flow.

Enclosure unit design guide

Inlet and outlet types

Air inlet and outlet should use grid or mesh types; avoid louver type due to limited intake size.

Vent opening design guide

Follow guide for enclosure unit. Minimum opening ratio is 50%. Example calculation provided.

Partition design guide

Add partitions for air paths, ensuring perfect fit or filling gaps with foam tape. Install anti-backflow screen.

Single enclosure unit

Design enclosure to match unit inlet/outlet. Allow 50mm clearance. Total open area of ventilation holes 20,000 mm² or more.

Designing a 1 x N single-side enclosure

Ensure clearance (A) for air flow. For multiple displays, use separate fans (150 CFM) and maintain external air temp below 30°C.

Designing a double-side enclosure

Ensure clearance (A) for air flow. Use separate fans (300 CFM) and maintain external air temp below 30°C. Ensure lower inlet is adequate.