Disassembly & Reassembly
3-6 Samsung Electronics
3-1-11 Separation of ASSY PDP MODULE P-Y MAIN & BUFFER BOARD
Part Name Description Description Photo
Flat Cable
①
Detach the 6 scan board connectors
from the panel by pulling the holder from
both the top and bottom ends.
Y-Main
Board
①
Detach all connectors from the Y-Main
Board.
②
Remove 9 screws.
: PH,+,WWP,M3,L8,NI PLT,SWRCH18A,
③
Remove the Y-Main Board.
Y-Buffer
Upper &
Lower
Board
①
Remove 8 screws.
: PH,+,WWP,M3,L8,NI PLT,SWRCH18A
②
Remove the Y-Buffer Upper & Lower
Board.