4.Troubleshooting
MethodofColorCalibration(A V)
1)ApplytheNTSC/PALLattice(N0.3)patternsignaltotheA VIN1port.
2)PresstheSourcekeytoswitchto“A V1”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“A VCalibration”menu.
6)In“A VCalibrationOff”status,pressthe
keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“A VCalibration”statusfromFailuretoSuccess.
MethodofColorCalibration(Component)
1)Applythe720pLattice(N0.6)patternsignaltotheComponentIN1port.
2)PresstheSourcekeytoswitchto“Component1”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“CompCalibration”menu.
6)In“CompCalibrationOff”status,pressthe
keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“CompCalibration”statusfromFailuretoSuccess.
MethodofColorCalibration(PC)
1)ApplytheVESAXGALattice(N0.21)patternsignaltothePCINport.
2)PresstheSourcekeytoswitchto“PC”mode.
3)EnterServicemode.
4)Selectthe“ADC”menu.
5)Selectthe“PCCalibration”menu.
6)In“PCCalibrationOff”status,pressthe
keytoperformCalibration.
7)WhenCalibrationiscomplete,itreturnstothehigh-levelmenu.
8)Youcanseethechangeofthe“PCCalibration”statusfromFailuretoSuccess.
4-40Copyright©1995-2011SAMSUNG.Allrightsreserved.