Items
Model
14
PRODUCT SPECIFICATIONS
Compressor
Evaporator
Model
First Defrost Cycle (Concurrent defrost of F and R)
Defrost Cycle(FRE)
Defrost Cycle(REF)
Pause time
THERMISTOR
(F-SENSOR)
502AT
Temperature Selection
-8℉(-22℃)
-2℉(-19℃)
8℉(-13℃)
Model
THERMISTOR
(R-SENSOR)
502AT
F Defrost-Sensor
R Defrost-Sensor
F Bimetal-thermo
Protector
R Bimetal-thermo
Protector
Temperature Selection
34℉(1℃)
38℉(3℃)
46℉(8℃)
Model
SPEC
Model
SPEC
Rated
Operating temperature
Rated
Operating temperature
Condenser
Dryer
Capillary tube(Dia x Length)
Refrigerant
Model
Starting type
Oil Charge
Freezer
Refrigerator
BK190CL2C/E02
R.S.C.R
FREOL α- 10
SPLIT FIN TYPE
SPLIT FIN TYPE
Forced and natural convection type
Molecular sieve XH-9
0.032” x 118” (0.81mm x 2997mm)
R134a
11hr ±10min
11~22hr(vary according to the conditions used)
6~11hr(vary according to the conditions used)
12 ±1min
THERMISTOR (502AT)
5.0 ㏀ at 77℉(25℃)
THERMISTOR (502AT)
5.0 ㏀ at 77℉(25℃)
AC 125V 10A
Off : 140℉(60℃) / On : 104℉(40℃)
AC 125V 10A
Off : 140℉(60℃) / On : 104℉(40℃)
ON(℉)
-2℉(-19℃)
1℉(-17℃)
11℉(-12℃)
ON(℉)
36℉(2℃)
40℉(4℃)
48℉(9℃)
OFF(℉)
-13℉(-25℃)
-5℉(-21℃)
5℉(-15℃)
OFF(℉)
32℉(0℃)
36℉(2℃)
44℉(7℃)
Specification
RF267 / RF26X
Components for FreezerDefrost Related Components
FreezerRefrigerator
Defrost Cycle
Defrost SensorBimetal
Room Temperature Sensor Components
AW-SEM Transform(RF267,2#3957D8 2009.8.20 4:50 PM 페 이 지 1 4 i n