3
SPEC
Item
Model
Power
AC 220V/50Hz
Compressor
Model
Lube
Evaporator
Condenser
Drying filter
Capillary
Molecular sieve
SILK PIPE
Built-in
Temp.
Control
Start up relay
Freeze
Refrigerating
Deputy evap
Initial resistance
Model
Model
SPEC
SPEC
SPEC
SPEC
SPEC
SPEC
ON temp
OFF temp
Earthing
screw
Lamp
DC motor
E-magnetic
valve
Door light
switch
ID 0.72 L2800mm
Sensor 502AT
Sensor 502AT
Sensor 502AT
8100(ID A) 8100(ID B)
GQS70AA
ESTER OIL
3. SPEC. AND CRITERION OF ELECTRIC & COOLING PARTS
Cooling cycle
Electric spare parts
Capacitor
Overload
protector
11-19
9-16
B63-125
T0455
70-55
70-55
120-130
120-130
DC 12V 0.08A
240V 25W
220V 0.5A / 125V 1.5A
COPPER SCREW BSBN
4uF,400V
SDF0.83/2-3B