No Error Items Display LED TROUBLE
1 Fridge Sensor
Fridge
"Mid"
Fridge Room Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
2
Peripheral Temp
Sensor
Fridge
"Min"
Ambient Temp. Sensor Error- This can be a wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
3 Freezer Sensor
Freezer
"Max"
Freezer Room Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
4
Freezer Defrost
Sensor
Freezer
"Mid"
Freezer Room Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 149° or < -58 ° F.
5
Freezer Defrost
Error
Freezer
"Min"
Freezer Room defrosting heater- wire cut, short-circuit, contact failure,
missing sensor housing, or defective temperature fuse/bi-metal. Defrost
on for over 90 minutes
6
I/M Function
Error
No Ice
This error indicates the Ice tray has not returned to level after an ice
harvest. The error is displayed after three failed attempts.
7 I/M Sensor Error Cubed Ice
Ice Maker Sensor Error- This can be a wire cut, short-circuit, contact
failure, or missing sensor. This can also be caused by a temperature
Samsung 'Refrigerator' Diagnostic Code Quick Guide
Samsung Single Evaporator 'Refrigerator' Diagnostic Code Quick Guide
reading > 149° or < -58 ° F.
No Error Items Display LED TROUBLE
1 R-SENSOR
Fridge
5
Fridge Compartment Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
2
DEFROST
SENSOR, R
ROOM
Fridge
d
Fridge Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
This can also be caused by a temperature reading > 150° or < -58 ° F.
3
Peripheral Temp
Sensor
Freezer
E5
Ambient Temp. Sensor Error- This can be an wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
4 F-SENSOR
Freezer
F5
Freezer Compartment Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 150° or < -58 ° F.
5 F-DEF-SENSOR
Freezer
d5
Freezer Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
This can also be caused by a temperature reading > 150° or < -58 ° F.
Samsung Older "RB" Series 'Refrigerator' Diagnostic Code Quick Guide