45
4. TROUBLESHOOTING
ITEM OPTION ITEM
ICE-MAKER WATER
SUPPLY QTY CONTROL
2
3) Ice-Maker Water Supply
It controls the water supply quantity
with the Flow Sensor.
Option Value
Option Item
WATER SUPPLY QUANTITY OPTION ITEM
104CC
114CC
0
1
Ex) Changing the water supply
quantity to 104cc
4) Ice-Maker Ice Ejection Standby Time
Controlling
; It is an option controlling the Ice Ejection
Standby time of the Ice-Maker.
ITEM
DISPLAY LOCATION
(FRIDGE TEMP)
ICE MAKER Ice
Ejection Standby Time
3
Standby Time
Freezer Display
50min
0
47min
1
45min
2
53min
3
55min
4
60min
5
65min
6
70min
7
50min
8
50min
9
50min
10
50min
11
50min
12
50min
13
50min
14
50min
15
5) Ice-Maker Sensor Temp Shifting
- It is an option shifting the ice ejecting base temperature.
ITEM
DISPLAY LOCATION
(FRIDGE TEMP)
Ice-Maker Sensor
Temp Shifting
4
Ice-Maker
Sensor Temp
Freezer Display
-7.5
°C ( 18.5°F)
0
-7.0
°C ( 19.4°F)
1
-6.5
°C ( 20.3°F)
2
-8.0
°C ( 17.6°F)
3
-8.5
°C ( 16.7°F)
4
-9.0
°C ( 15.8°F)
5
-9.5
°C ( 14.9°F)
6
-10.0
°C ( 14°F)
7