Ice comes out when
extracting it.
56
4. TROUBLESHOOTING
4-17) When Crush (Crushed Ice) & Cube (Cubed Ice) does not operate well
Only for Dispenser models
Start
① Check switches related with ICE
② Check door switches
③ Check motors related with ICE
④ Check wire connection
⑤ Check if the Cover ICE ROUTE
opens.
MAIN PBA is normal.
-- Check other parts.
① Check wires between
AUGER MOTOR
↔MAIN
PBA
② Defective CUBE Solenoid or
Defective Connector
Contacts
MAIN PBA is normal.
-- Check other parts.
① Check wires between
AUGER MOTOR↔MAIN PBA
Freezer door should be
closed during operation.
① Check if water hose is bent or
closed.
② Check Water Supply for Ice-
Maker and Solenoid
③ Check Ice-Maker wires
④ Check Ice-Maker Kit
Cancel Ice Off→
Select Cubed/
Crushed
Normal Operation
Ice S/W or Wire
Defect
Main PBA Defect,
Replace it
Replace SSR74 or
RY7C
Normal Operation
Ice S/W or Wire
Defect
MAIN PBA Defect - Replace
it
Replace it RY7B
NO
Crushed
Cubed
NO
YES
YES
YES
YES
NO
NO
NO
Ice Selection is
Cubed Ice comes out.
When Ice S/W is
pressed, CN50 #6
changes to 0V.
When Ice S/W
is pressed, IC73 #11
changes to 0V
When Water
& Ice S/W is pressed,
the voltage across CN70 #3 &
CN73 #11 is about AC 230V
(or 115V)
YES
NO
YES
YES
YES
NO
NO
NO
Crushed
Ice comes
out.
When Ice S/W is pressed,
CN50 #6 changes to 0V.
When Ice S/W
is pressed, IC73 #12
changes to 0V
When Water &
Ice S/W is pressed,
the voltage across CN70 #3 &
CN73 #9 is about
AC 230V(or 115V)
Ice is in the Ice
bucket.
NO
NO
YES
YES
YES
Ice Off is selected
on the Display Panel