CN 73 120vac Loads
1-(CN70-3) Water Valve (Wht/Blk-Red)
7 -(CN70-3) Ice Valve (Vio-Red)
9 -(CN70-3) Auger Mtr (Pnk-Red)
11-(CN70-3) Cube Solenoid (Yel-Red)
CN 70 + CN71 120vac Loads
1 Neutral (Blk)
3 L1 (Red)
5-7 Defrost Heater (Brn-Org)
11-3 Comp (S/Blu-Red)
13 Neutral (Blk)
15-3 Dispenser Htr (Blu-Red)
CN 40 Sensors & Switches
1-2 Ext Sensor (Yel-Yel) 1.2~2vdc
3-4 Frz Door Sw (Wht/Grn-Gry) 0 or 5vdc
5-(CN50-5) Freezer Sensor (Yel-Gry) 3.5~4.2vdc
6-(CN50-5) Frz Def Sensor (Blu-Gry) 2.3~4.2vdc
7-8 Ref Door Sw (Wht/Red-Gry) 0 or 5vdc
9-(CN50-5) Ref Sensor (Blk-Gry) 2.4~2.8vdc
CN 76 Cool Zone
4-5 Damper Htr (Blk-Brn) 13vdc
3-4 Stepper Mtr (Wht-Blu)
8-9 Stepper Mtr (Yel-Red)
CN 51 Display Panel
1-7 Panel Data
14 vdc Common
CN 75 Fans
2-10 Cond Mtr (S/Blu-Gry) 7~12vdc
4-10 Frz Evap Mtr (Yel-Gry) 7~12vdc
5-FG Frz Evap Mtr (Blk)
7-FG Cond Mtr (Red)
CN 90 I/M
1-2 I/M Mtr (Red-Blk) 12vdc
3-8 Eject Sensor (Wht-Gry) 2.3~3.3
4-8 Test Sw (S/Blu-Gry)
5 Hall IC out (Prp)
7-8 5vdc (Blu-Gry)
CN 78 LED Lights 13vdc
1-2 Frz LEDs (Brn-Gry)
3-5 Frg LEDs (S/Blu-Gry)
4-5 Frg LEDs (Prp-Gry)
CN 50 Dispenser Switches
4 To Panel PCB pin 13 (Wht/Yel)
5 Sensor DC common (Gray)
6-10 Ice Sw (Yel-Gry)
7-10 Water Sw (Pnk-Gry)
8 & 15 Tied together (Prp)
13 To Panel PCB pin 12 (Wht/Red)
First Defrost Cycle 4 hr ± 10 min
Defrost Cycle (FRE) 16~40hr (vary according to the conditions used)
Pause time 10 ± 2 min