Loading...
21
8. Various OPTION function
8-1. TABLE OF TEMPERATURE CHANGE OF REFRIGERATOR(
:RELEVANT DIODE NO. USED)
()
D601
D602
D603
D604
D605
D606
D607
D608
D609
D6010
D611
D612
D613
D614
D615
D616
D617
D618
D619
D620
MICOM
OUTPUT1
INPUT1
INPUT2
INPUT3
INPUT4
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
-0.5
-1.0
-1.5
-2.0
-2.5
-3.0
-3.5
-4.0
-4.5
-5.0
-5.5
-6.0
-6.5
-7.0
-7.5
+0.5
+1.0
+1.5
+2.0
+2.5
+3.0
+3.5
+4.0
+4.5
+5.0
+5.5
+6.0
+6.5
+7.0
+7.5
+8.0
605 604 603 602 601 605 604 603 602 601SHIFT SHIFT
Warning) As DIODE OPTION except D601-D605 has important effects on the reliability of
refrigerator, do not change it voluntarily!!!