4-5-2. Service Function
Checking the Code Version
Enter the service mode, and check the MCU code version and checksum.1.
Entering the Service Mode2.
Adjust the brightness and contrast ratio to 0. -
Press and hold the Enter button for about 5 seconds. -
The SVC Function screen will be displayed. -
To close SVC Function, turn the power off. -
Safe Mode3.
If the input signal is higher than the frequency supported by the product, the safe mode will turn the graphics card -
setting to recommended mode for about 1 minute.
Monitor On Time : 0 Hr
Panel Ch. No. : 0
On Time : 0 Hr
Cycle : 10
Auto Auto : On
Pixelshift : Off
Country : English
Scaler-MCU : Novatek NT68650
Version : m-S119N0GFa-0900.0
Checksun : FE95
Service Function
Panel Information
Micom Version
Micom Checksum
Select the Auto option
Select the PixelShift option.
Country
Scaler Vender