EasyManua.ls Logo

Samsung SCL700 - Cue and Rev Check; Tracking Check; Check after Adjustment

Samsung SCL700
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 2-9
Adjustment
2-5-4 Check After Adjustment
2-5-4 (A) TRACKING CHECK
1. Play back the alignment tape.
2. Then, Confirm that the minimum amplitude
value (E min.) is 65% of the maximum value
(E max.) or larger. (Fig. 2-13)
3. Confirm that no large fluctuations occur on the
waveform. (Fig. 2-14)
Fig. 2-13
E
MIN
E
MAX
E
MIN
65(%)
E
MAX
2-5-4 (B) CUE AND REV CHECK
1. Play back the alignment tape, and set to REV
mode. Confirm that the waveform peaks have a
uniform pitch. (Fig. 2-15 )
2. Set to CUE mode.
Confirm that the waveform peaks still have a
uniform pitch. (Fig. 2-15 )
Fig. 2-15
a b c a b c
Fig. 2-14
A
C
C
C
1
A
8
a
=
b
=
c
A
>
=
B
<
=
A
B

Table of Contents