3. Disassembly and Reassembly
3-19
Samsung Electronics
Service Manual
SCX-483x/5x3x series
3.3.10 Fuser unit
CAUTION
The temperature gets high in the vicinity of the fuser unit. When replacing it, you may get injured. Before
replacing it, make sure that fuser unit has cooled.
1. Open the Frame-Rear by pushing both green
points.
2. Remove the Frame-Rear by releasing both
hooks.
3. Remove the exit sensor holder after removing
2 screws.
4. Remove 4 screws.
CAUTION
When reassembling the fuser unit, do not forget to
tighten these screws.
5. Release the fuser unit.
Frame-RearFrame-Rear
Exit sensor holderExit sensor holder