EasyManua.ls Logo

Samsung SH09YAB - Connecting the Assembly Cable; Installing and Connecting the Indoor Unit Drain Hose; To Install the Drain Hose

Samsung SH09YAB
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-7
Samsung Electronics
Operating Instructions and Installation
To install the drain hose, proceed as follows.
1. If necessary, connect the 2-metre extension to the drain hose.
2. If you are using the extension, insulate the inside part of the extension drain hose with a shield.
3. Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight.
4. Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as
shown in the illustrations above.
3-2-2(d) Installing and Connecting the Indoor Unit Drain Hose
Care must be taken when installing the drain hose for the indoor unit
to ensure that any condensation water is correctly drained outside.l
When passing the drain hose through the 65mm hole drilled in the
wall, check that none of the following situations occur.
3-2-2(c) Connecting the Assembly Cable.
1(N) 2 3 4 5
1 5432
A B C D E
The outdoor unit is powered from the indoor unit via the assembly
cable. If the outdoor unit is more than five metres away from the
indoor unit, the cable must first be extended to a maximum of ten
metres.
1. Extend the assembly cable if necessary.
2. Open the front grille by pulling on the tabs on the lower right and
left sides of the indoor unit.
3. Remove the screw securing the connector cover.
4. Pass the assembly cable through the rear of the indoor unit and
connect the assembly cable to terminals 1(N) to 5.
Each wire is labelled with the corresponding terminal number.
5. Firmly fix the assy cable with clamp wire holder.
6. Pass the other end of the cable through the 65mm hole in the wall.
7. Replace the connector cover, carefully tightening the screw.
8. Close the front grille.
9. For further details on how to plug the other end of the assembly
cable into the outdoor unit, refer to page 3-8.
The hose will be fixed permanently into position once
the whole installation has been tested for gas leaks;
Keep a clearance
of at least 5cm
between the end
of the hose and
the ground.
Do NOT bend the
hose in different
directions.
The end of the
drain hose must
NOT be placed in
water.
The hose must
NOT slope upw
ards.
Do NOT place the
end of the drain
hose in a hollow.
Shield
Drain hose Extension drain hose
Indoor unit
Out door unit
5cm
less
N1 1 2 3 E
1 5432
A B C D E
✳✳
YAB(X)
Indoor unit
Out door unit

Table of Contents

Other manuals for Samsung SH09YAB

Related product manuals