EasyManua.ls Logo

Samsung SR-606EV - Page 12

Samsung SR-606EV
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Samsung Electronics
(6) When refrigerator repaired, sure to power off and on to run self diagnosis.
(7) Refer to belows for problems and related displays.
No
1
2
3
4
5
6
7
Symptom
• R-room left sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room left right sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Room-Temp sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• F-room sensor housing
disconnection.
• Faulty connection
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Faulty geared-motor
• Faulty reed-switch
housing disconnection.
• Faulty connection.
Remark
R1-Sensor temperature is
over +50˚C or below –50˚C.
R2-Sensor temperature is
over +50˚C or below –50˚C.
RD-Sensor temperature is
over +50˚C or below –50˚C.
Room-Temp Sensor
temperature is over +50˚C
or below –50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
Square wave not detected
by reed-S/W.
Item
R1-Sensor
R2-Sensor
RD-Sensor
Room-Temp.
Sensor
F-Sensor
FD-Sensor
Geared-
Motor
Display LED
Refrigerator “Low”
Refrigerator
“Low · Mid”
Refrigerator “Mid”
Freezer “Low”
Freezer “Low”
Freezer “Mid”
Refrigerator “High”
(Self-diagnosis Display Table)