12-4 Trouble check for the cooling cycle
Symptom
Cause
Suggestions
The EVAP cools down and warms
again.
The condenser warms in proportion
as the EVAP cools.
The process continues to repeat.
Moisture in the refrigerant
causes the malfunction.
Replace the refrigerant
The condenser is cold.
The EVAP is not cold.
The temperature of the compressor
is high.
Foreign substances hamper
the cooling cycle.
Locate the disturbed section
and make repairs
No difference in temperatures
between suction pipe and discharge
pipe.
The temperature of the compressor
is maintained at room temperature.
The EVAP does not cool down.
The compressor is defective
Replace the compressor
Frost on the suction pipe.
The condenser is overheated.
The refrigeration in the EVAP is
not effecient.
Too much refrigerant Replace the refrigerant
The condenser is cold.
The compressor surface
temperature is high.
The refrigerator is not easily get
cooled.
Refrigerant leaks.
(Slight refrigerant leakage
causes partial cooling with
frost on the EVAP)
After welding the leaked spot,
replace the refrigerant