E-
45
ENGLISH
Performing Leak Tests
COMPLETING THE INSTALLATION
B
A
CD
The designs and shape are subject to
change according to the model.
Before completing the installation (insulation of the cables, hose and
piping and fixing of the indoor unit to the installation plate), you must
check that there are no gas leaks.
To check for gas leaks on the... Then, using a leak detector,
check the...
Indoor unit Flare nuts at the end of sections
C and D.
Outdoor unit Valves on sections A and B.