40 _ Troubleshooting
Check Type Check Mode Causes Corrective Actions Description of Photo
WaterSupply
Check
4C
• Watersupplyvaluefault
• MainPCBfault
• Freezinginthewinter
season
• Ifthewatersupplyvalvehasawire
disconnected,replaceit.
• Checkwhetherthewatersupplyvalveis
cloggedwithforeignmaterialandwhether
waterissuppliedcontinually.
• Checkwhethernowaterissuppliedbecause
offreezinginthewinterseason.
• IfthePBArelayoperatesabnormally,replace
thePBA.
1. Checktheresistanceforthewater
supplyvalve.
- Resistance:0.9~1.1kΩ
betweentheterminalsofthewater
supplyvalve.
2. Checkwhetherthereisforeign
materialinthewatersupplyvalve
lter.
3. Ifthewatersupplyvalvelteris
clogged,cleanlter.
DrainCheck 5C
• Freezinginthewinter
season
• Foreignmaterialsinthe
drainpump
• Poorphysicalconnection
• Drainpumpfault
• MainPCBfault
• Ifthedrainpumprevolutionsarerestrained
duetofreezinginthewinterseason,check
themethodtoremovethefreezingand
removeasdirected.
• Checkwhethertherevolutionsofthedrain
pumpmotorarerestrainedbyforeign
material,andremoveasdirected.
• CheckthewireconnectorsonMainPCBand
DrainPumpASSY.Theconnectororwire
mayhavepoorphysicalconnection.
• Checkthedrainpumpresistance.
Checkthedrainpumpresistance.
-Drain:
Resistance:13.5Ω~16.5Ω
-Bubble:
Resistance:18.75Ω~22.75Ω
Communication
Check
AC
• Thesignalsbetweenthe
subandmainPBAsare
notsensed.
• Incorrectwire
connectionsbetweenthe
subandmainPBAs.
• Checkthewireconnectionsandterminal
contactsbetweenthesubandmainPBAs.
• Checkfordisconnectedwires.
• CheckwhetherthesubPBAisshort-circuited
becauseofmoisture.
• IfthemainPBA’scommunicationcircuitis
faulty,replaceit.
-
WD6500K_7-8-9-11kg_1400rpm-SM.indb 40 2018/11/9 9:53:32