Installation
English24
Installation
STEP 5 Position the drain hose
The drain hose can be positioned in three ways:
A
Over the edge of a wash basin
The drain hose must be placed at a height
of between 60 cm and 90 cm (*) from the
oor. To keep the spout of the drain hose
bent, use the supplied plastic hose guide
(A). Secure the guide to the wall using a
hook to ensure stable drainage.
ln a sink drain pipe
The drain pipe must be above the sink
siphon so that the end of the hose is at
least 60 cm above the oor.
ln a drain pipe
The drain pipe should be between 60 cm
and 90 cm high (*). It is advisable to use
a 65 cm high vertical pipe. Make sure the
drain hose is connected to the stand pipe
at a slant.
Drain standpipe requirements:
Minimum diameter of 5 cm
Minimum carry-away capacity of
60 litres per minute