EasyManuals Logo

S&P RESPIRO Series User Manual

S&P RESPIRO Series
Go to English
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
27
ENGLISH
TECHNICAL PARAMETERS
The recovery unit is classifi ed as a Class II product.
The degree of protection is IPX4.
The recovery unit has been designed to be installed in closed places. The operating temperatures are between -20°C and
50°C with maximum relative humidity 80%.
The design of the recovery unit is constantly evolving, therefore, certain models could differ from that detailed in this ma-
nual.
RESPIRO 100 / RESPIRO 100 RD
RESPIRO 100
Speed 1 2 3
Voltage at 50Hz 220-240 Vac 220-240 Vac x
Power [W] 3,9 7,9 x
Capacity [m³/h] 15 30 x
Noise at 3 m [dB] 19 29 x
Max heat recovery 93% 93% x
Average heat recovery 70% 78% x
RESPIRO 100 RD
Speed 1 2 3
Voltage at 50Hz 220-240 Vac 220-240 Vac 220-240 Vac
Power [W] 3,9 5,9 7,9
Capacity [m³/h] 15 22,5 30
Noise at 3 m [dB] 19 24 29
Max heat recovery 93% 93% 93%
Average heat recovery 70% 74% 78%

Table of Contents