SM2000 Dry Ice Cleaning Machine User Manual and Maintenance Guide
Troubleshooting
Fault
Reasons
Troubleshooting Steps
1
No Dry Ice Output
1. Check if the compressed air is
properly turned on.
Open the air valve
switch.
2. Check if the air solenoid valve is
open.
Inspect and replace if
necessary
3. Verify if the dry ice delivery
system is running.
Check if the motor
operates correctly.
2
Remote Control
Doesn’t Work
1. Confirm if the remote control has
sufficient battery power
Check and replace the
batteries if needed
2. Check if the wiring of the remote
control receiver module is correct
or loose.
Inspect, repair, or
replace the wiring
3. Incorrect pairing between the
receiver module and the remote
control.
Re-pair the devices.
4. Control circuit malfunction
Test the control circuit
and resolve any issues.
10