FAULT FINDING
Identify the exact cause of the appliance stoppage
The paddles do not turn:
• Make sure that you have indeed actuated (position 1) the respective switches (8)
• Check the mains power supply and the condition of the power supply lead.
Liquid drips from the distribution nozzle:
• Clean the flexible distribution spout (5) (a solid body is probable stuck inside).
• The flexible spout (5) is a consumable. For hygiene reasons, do not hesitate to
replace it regularly
The appliance overheats:
• Ventilation is required to ensure the proper performance of the appliance
• Make sure that the front and back ventilation vents (10) are not obstructed (leave a
gap of at least 15cm).
• Check that there is no dust on the condenser grid (clean using a soft brush)
o Access to the grid: remove the appliance side panels (9)
The temperature of the juice is too high:
• See previous section "the appliance overheats"
• Depending on the volume of product and the ambient temperature, it is sometimes
necessary to wait several hours before reaching the desired temperature.
• If after stabilisation the temperature is inadequate, then adjust the thermostats (12)
(one per juice container; it is recommended that the same setting is used on all the
thermostats)
o Access to the thermostats: remove the appliance side panels (9)
• For multi-container appliances (2 or 3 containers), leaving at least one container
with no liquid is not recommended.
o Frost quickly forms on the evaporation cup (4) and the thermostat is quickly
triggered, thus stopping the compressor. The other containers are no longer
cooled.
o Always fill the containers with a minimum of 5 cm of liquid
The appliance runs continually without cooling the juice:
• Have the system checked by a refrigeration engineer
• The refrigerant charge is stated on the appliance identification plate.
• Draining and filling the condensing unit is absolutely prohibited in any place not
equipped to collect such gasses.
• Do not use anything other than R134A