SANTOS: User and maintenance manual
98155 EN 3.7- 05 2014 11 / 22 www.santos.fr
Setting the measured dose of ground coffee (timers):
The ground coffee outlet tube (23) should be cleaned regularly to prevent the coffee which
has built up on the walls from interfering with the consistency of the coffee dose
measurement (fig. H).
IMPORTANT: Check or adjust the grinding before setting the timers.
Where the timers are being set following adjustment
of the grinding, you can use the chart BELOW
Explanatory notes for the table:
For example: you have made your grinding setting, which corresponds to "Notch 6" on the
grinding adjustment nut (5). If you want to obtain a 7g measure of coffee, you will need to
set the value of the timer to between 080 and 090 for an espresso type coffee.
!
Approximate values for one measure and for new SANTOS grindstones
3
4
5
6
7
8
9
10
11
2 3 4 5 6 7 8 9 10 11 12
Measure dispensed (g)
Adjusting the fineness of grinding
(Mark on the nut graduated plate (5))
60
70
80
90
Timer